POLSTAT is designed for precise temperature controlling of small scale reactors including all glass reactors or glass assemblies. Research & Developed by POLMON with highly efficient components gives you precise temperature controlling. These temperature control units cover all the temperature range in between (-) 20°C To (+) 200°C. Best suitable in labs where plant utilities are not available but precise heating & cooling is must.
General Technical Specifications
S.No | Title | Value |
---|---|---|
1 | Vessel Range | 1L To 500L |
2 | Minimum Jacket Temperature (°C) | (-)20 |
3 | Maximum Jacket Temperature (°C) | 200 |
4 | Heater Capacity (KW) | As Per Heat Load |
5 | Cooling Capacity (TR) | As Per Heat Load |
6 | Pump Flow Rate (LPM) | As Per Heat Load @ 0.4 Bar |
7 | Temperature Stability | ± 0.5°C |
8 | Heating Rate | Approx 1 ℃ Per Minute |
9 | Cooling Rate | Approx 0.5 ℃ Per Minute |
10 | Heat Transfer Medium | Synthetic oil |
11 | MOC (Wetted Parts) | SS304 |
12 | Display Module | 4" HMI |
13 | Jacket Temperature Sensor | Built in-Pt100 |
14 | Mass Temperature Sensor | Pt100 External (Client Scope) |
15 | Approx Dimensions In mm (W x D x H) | 600X800X1000 |
16 | Power Supply | 230 V AC, 50 Hz OR 440VAC, 50Hz |
17 | Connectivity | Ethernet and RS 485 |
Features
POLMON brings you portable temperature control unit specially designed for all glass reactors/glass assemblies
Highly dynamic and specially designed for temperature controlling of small scale reactors.
Bes t suitable for Pilot Plant, Kilo Lab and R&D labs for precise temperature control of the reactors.
Compact and elegant design.
Highly efficient in handling endothermic as well as exothermic reactions resulting in high yield.
Comes with all required safety interlocks for safety of user, reactor and product itself.
Can be integrated with PLC and SCADA.
21 CFR Part 11.
User friendly operational interface.
Plug & Play type.
Polstat1000 Models Vs Heat and cooling capacities
Sr. No | Vessel Capacity (Ltr) | Chiller Type | Model Number | Heating Capacity(KW) | Cooling Capacity (KW) 0°C |
---|---|---|---|---|---|
1 | 10 | Air Cooled | POLSTAT1000-10a :(-)20ᵒC to 200ᵒC | 2 | 2 |
2 | POLSTAT1000-10a :(-)40ᵒC to 200ᵒC | 2 | 2 | ||
3 | POLSTAT1000-10a :(-)60ᵒC to 200ᵒC | 2 | 2 | ||
4 | POLSTAT1000-10a :(-)80ᵒC to 200ᵒC | 2 | 2 | ||
5 | Water Cooled | POLSTAT1000-10w :(-)20ᵒC to 200ᵒC | 2 | 2 | |
6 | POLSTAT1000-10w :(-)40ᵒC to 200ᵒC | 2 | 2 | ||
7 | POLSTAT1000-10w :(-)60ᵒC to 200ᵒC | 2 | 2 | ||
8 | POLSTAT1000-10w :(-)80ᵒC to 200ᵒC | 2 | 2 | ||
9 | 20 | Air Cooled | POLSTAT1000-20a :(-)20ᵒC to 200ᵒC | 3 | 2.5 |
10 | POLSTAT1000-20a :(-)40ᵒC to 200ᵒC | 3 | 2.5 | ||
11 | POLSTAT1000-20a :(-)60ᵒC to 200ᵒC | 3 | 2.5 | ||
12 | POLSTAT1000-20a :(-)80ᵒC to 200ᵒC | 3 | 2.5 | ||
13 | Water Cooled | POLSTAT1000-20w :(-)20ᵒC to 200ᵒC | 3 | 2.5 | |
14 | POLSTAT1000-20w :(-)40ᵒC to 200ᵒC | 3 | 2.5 | ||
15 | POLSTAT1000-20w :(-)60ᵒC to 200ᵒC | 3 | 2.5 | ||
16 | POLSTAT1000-20w :(-)80ᵒC to 200ᵒC | 3 | 2.5 | ||
17 | 50 | Air Cooled | POLSTAT1000-50a :(-)20ᵒC to 200ᵒC | 6.5 | 4.66 |
18 | POLSTAT1000-50a :(-)40ᵒC to 200ᵒC | 6.5 | 4.66 | ||
19 | POLSTAT1000-50a :(-)60ᵒC to 200ᵒC | 6.5 | 4.66 | ||
20 | POLSTAT1000-50a :(-)80ᵒC to 200ᵒC | 6.5 | 4.66 | ||
21 | Water Cooled | POLSTAT1000-50w :(-)20ᵒC to 200ᵒC | 6.5 | 4.66 | |
22 | POLSTAT1000-50w :(-)40ᵒC to 200ᵒC | 6.5 | 4.66 | ||
23 | POLSTAT1000-50w :(-)60ᵒC to 200ᵒC | 6.5 | 4.66 | ||
24 | POLSTAT1000-50w :(-)80ᵒC to 200ᵒC | 6.5 | 4.66 | ||
25 | 100 | Air Cooled | POLSTAT1000-100a :(-)20ᵒC to 200ᵒC | 12 | 7.33 |
26 | POLSTAT1000-100a :(-)40ᵒC to 200ᵒC | 12 | 7.33 | ||
27 | POLSTAT1000-100a :(-)60ᵒC to 200ᵒC | 12 | 7.33 | ||
28 | POLSTAT1000-100a :(-)80ᵒC to 200ᵒC | 12 | 7.33 | ||
29 | Water Cooled | POLSTAT1000-100w :(-)20ᵒC to 200ᵒC | 12 | 7.33 | |
30 | POLSTAT1000-100w :(-)40ᵒC to 200ᵒC | 12 | 7.33 | ||
31 | POLSTAT1000-100w :(-)60ᵒC to 200ᵒC | 12 | 7.33 | ||
32 | POLSTAT1000-100w :(-)80ᵒC to 200ᵒC | 12 | 7.33 | ||
33 | 200 | Air Cooled | POLSTAT1000-200a :(-)20ᵒC to 200ᵒC | 21 | 12.67 |
34 | POLSTAT1000-200a :(-)40ᵒC to 200ᵒC | 21 | 12.67 | ||
35 | POLSTAT1000-200a :(-)60ᵒC to 200ᵒC | 21 | 12.67 | ||
37 | Water Cooled | POLSTAT1000-200w :(-)20ᵒC to 200ᵒC | 21 | 12.67 | |
38 | POLSTAT1000-200w :(-)40ᵒC to 200ᵒC | 21 | 12.67 | ||
39 | POLSTAT1000-200w :(-)60ᵒC to 200ᵒC | 21 | 12.67 | ||
45 | 300 | Water Cooled | POLSTAT1000-300w :(-)20ᵒC to 200ᵒC | 25 | 12.67 |
46 | POLSTAT1000-300w :(-)40ᵒC to 200ᵒC | 25 | 12.67 | ||
53 | 500 | Water Cooled | POLSTAT1000-500w :(-)20ᵒC to 200ᵒC | 35 | 19.305 |
54 | POLSTAT1000-500w :(-)40ᵒC to 200ᵒC | 35 | 19.305 | ||
57 | 750 | POLSTAT1000-750a :(-)20ᵒC to 200ᵒC | |||
58 | POLSTAT1000-750a :(-)40ᵒC to 200ᵒC | ||||
59 | POLSTAT1000-750a :(-)60ᵒC to 200ᵒC | ||||
60 | POLSTAT1000-750a :(-)80ᵒC to 200ᵒC | ||||
61 | POLSTAT1000-750w :(-)20ᵒC to 200ᵒC | ||||
62 | POLSTAT1000-750w :(-)40ᵒC to 200ᵒC | ||||
63 | POLSTAT1000-750w :(-)60ᵒC to 200ᵒC | ||||
64 | POLSTAT1000-750w :(-)80ᵒC to 200ᵒC | ||||
57 | 1000 | Water Cooled | POLSTAT1000-1000w :(-)20ᵒC to 200ᵒC | 65 | 37.0305 |
58 | POLSTAT1000-1000w :(-)40ᵒC to 200ᵒC | 65 | 37.0305 | ||
59 | 2000 | Water Cooled | POLSTAT1000-2000w :(-)20ᵒC to 200ᵒC | 125 | 71.253 |
60 | POLSTAT1000-2000w :(-)40ᵒC to 200ᵒC | 125 | 71.253 |